Long Workshop Kit Building
A Structure in Kit Form being 30’-0” Span x 60’-0” Long in 3 No 20’-0” Bays x 12’-0” to Eaves.
SPECIFICATION
This Structure will be designed to a full Agricultural Class II BS 5502 Specification.
Manufactured in accordance with EN: 1090 Execution Class 1.
DRAWINGS
This quotation includes for all full set of Drawings to assist you in the complete construction of your proposed building.
STEELWORK
All steelwork will receive 1 No Coat of High Build Phosphate Grey Oxide Paint prior to delivery. A small of touch up will be included in your delivery.
STEEL COMPONENTS
8No Main Stanchions.
8 No Main Portal Rafters @ 10 Deg Roof Pitch.
1 No Gable Stanchions.
2 No Roller Shutter Door Posts
2 No Diagonal Roof Bracings in Box Section
1 No Personnel Door Frame
12 No Angle Knee Bracings
11 No Amount of Various Thickness Packer Plates
2 No Tonnes of Structural steelwork.
BOLTS
We have allowed all high tensile zinc plated structural steel bolts washers and nuts.
FOUNDATION BOLTS
We have allowed all holding down bolts, washer plates and cardboard cones for foundation pads below floor level. We can supply Resign anchors if required.
Personal Access Doors
Included in the price
TIMBER EAVES BEAMS
We have allowed 2 No Lines of 3” x 9” Treated timber eaves beams Secured at the stanchion top acting as a support for the roof and vertical cladding.
TIMBER PURLINS
We have allowed 8 No Lines of 3” x 9” Treated Timber Purlins Secured to the main rafters acting as a support for the roof cladding.
TIMBER CLADDING RAILS
We have allowed 2 No Lines of 3” x 7” Treated Timber Cladding Rails Fixed to the main stanchions acting as a support for any vertical cladding.
ROOF CLADDING
The whole of the roof will be clad in:
Bigsix Profile Natural Grey single skin sheeting with closed crown sheets.
ROOF LIGHTS
We have allowed 6 No 7’-0” Long Single Skin Roof lights. Please be aware of condensation under the right conditions.
VERTICAL CLADDING
We have allowed to supply :
.5th Plastisol coated single skin box profile steel sheeting colour to be agreed.
To the areas as stated below complete with all flashings and fixings.
Side One Sheeted to the floor
Side Two Sheeted to the floor
Gable One Sheeted to the floor
Gable Two Sheeted to the floor
Allowing for door openings
FLASHINGS
We have allowed for all flashings required to complete the contract.
DRIP FLASHINGS
The bases of the vertical cladding may require a bottom drip flashing depending on the cladding detail this building will NOT be fitted with a drip flashing.
PVC RAIN WATER GOODS
2 No Lines of 170mm Half Round Deep Flow Black PVC Guttering running down the eaves to both sides of the building. Fixed to a gutter facia at 1.000 crs complete with 1 No 110 Dia Rain Water Pipe per run terminating at floor level.
DOORS
By others
TIMBER
All Timber supplied with the contract will be of standard lengths and will need cutting to its exact length, and drilling on-site by the customer.
ACCESS AND UNLOADING
If you have any specific access or unloading requirements, please let us know asap.
PAYMENT TERMS
SUPPLY ONLY
25% Deposit with your order.
75% To be paid prior to delivery unless agreed otherwise.
DELIVERY
To be confirmed
Call Us Today On 01283 735 522 Request Your Free Quote